1st Run ORT with room temp. and all results positive (12 h 57 min, 21 nov 2017 ans – 19 h 32 min, 22 nov 2017 ans)
Description:
Based on below matrix, totally we executed 18 test cycles under room temperature.
Top 3 issues (QSFP, OBO and GNER PRBS) are correlated with previous one which found at TAO.
For #103 card, OBO PRBS is failed on TiN 1 OBO-0 twice.
For #040 card, QSFP PRBS is failed on TiN 0 and TiN 1 on different test cycle.
Aligned with RD team, we are fine to move forward Chamber ambient testing.
Ajouté au bande de temps:
Date:
12 h 57 min, 21 nov 2017 ans
19 h 32 min, 22 nov 2017 ans
~ 30 hours